P-Pack Databoxes

4 way plastic databox, with 25mm gland hole

(L) 188mm x (W) 62mm x (D) 42mm

£7.00

SKU: P-PACK 0/4D Category:

Description

P-Pack Databoxes

https://www.dataroomdirect.com/wp-content/uploads/2022/08/P-Pack-0-4.jpghttps://i.ytimg.com/vi/yU0kVbyRmLk/hq720.jpg?rs=AOn4CLArLQlbBIOmuCCNdH-Iyungi3rktA&sqp=-oaymwEhCK4FEIIDSFryq4qpAxMIARUAAAAAGAElAADIQj0AgKJD
6

Key Features

  • Volume-installation unit designed for sub-floor data systems, making it ideal for raised floor installations and structured cabling environments.

  • Standard “6C” cut-outs for terminating data cables/components (i.e., standard keystone/data modules) enabling easy integration of network/data outlets.

  • Gland entry holes keyed for flexible conduit. For example, variants include keyed gland holes for 35 mm or 32 mm conduit entry.

  • Durable construction: steel construction (or plastic/steel depending on variant) for longevity and suitability in commercial infrastructure.

  • Configurable orientation: units can be installed horizontally or vertically to suit different under­floor layouts and access arrangements.

Why Choose This Unit?

If you’re equipping an under-floor or raised floor office or data centre environment, the P-Pack Databoxes deliver a reliable, professional solution. Here’s why:

  • Simplifies data outlet installation: with standard 6C cut-outs and conduit entries, installers can deploy multiple data terminations into one box rather than many disparate units.

  • Flexible layout: the ability to orient the box horizontally or vertically adds installation flexibility especially in tight or unusual spaces.

  • High quality build: the steel or tough plastic housing (depending on version) ensures durability in commercial environments.

  • Integration friendly: designed for raised-floor systems where data/AV outlets and power/data conduits need clean routing beneath the floor surface.

  • Complements your power solutions: if you’re already using P-Pack under-desk and desktop power modules, choosing the same brand for data boxes ensures streamlined spec, consistent finish and simpler supply/installation chain.

Specification at a Glance

Spec Detail
Cut-outs Standard “6C” data terminations
Gland Holes Keyed glands: 35 mm or 32 mm flexible conduit entry
Orientation Horizontal or Vertical installation
Construction Steel (or tough plastic variant)
Typical Use Case Raised floor data outlet termination point
Accessories Required Conduit, flexible hose, data keystone modules, labelling

Note: As this is a data-termination box, actual data keystone modules, patch leads and conduit may need to be sourced separately based on your layout and specification.

Installation & Usage Tips

  • Ensure the sub-floor or raised floor panel location is accessible and that there is adequate clearance for conduit entry and data module access.

  • Select the correct orientation (horizontal or vertical) based on your floor void space, cable ingress/egress and future servicing needs.

  • Use the keyed gland hole for your flexible conduit or hose to ensure a secure, tidy entry — selecting the correct diameter (32 or 35 mm) conduit to match site standards.

  • Label the location of the box clearly at installation (e.g., “Row A – Workstation 5 – Data Box”) because under-floor boxes are less visible than on-desk modules.

  • Plan the data modules (6C) in advance: decide how many and which type of keystone modules you’ll place, so the box cut-outs are fully used and you avoid under-populating.

  • Consider future proofing: leave extra space or empty cut-outs for future network expansion (e.g., additional RJ45 ports, HDMI/AV, USB-C data etc).

Ideal For

  • Raised-floor office fit-outs where multiple data terminations are required in a centralized under-floor junction location.

  • Data/AV installations in meeting rooms, hot-desking zones or flexible workspaces where infrastructure is routed beneath the floor.

  • Installers and system integrators seeking a standardised, commercial-grade data box solution that aligns with your power infrastructure (e.g., P-Pack power modules).

  • Projects where tidiness, serviceability and professional finish are important (e.g., corporate offices, higher education, government PMO spaces).

What You’ll Receive

  • P-Pack Databox unit with specified number of 6C cut-outs and gland holes for conduit entry.

  • Installation instructions and mounting hardware (check variant for included fixings).

  • Note: Data keystone modules, patch leads, conduit/hose and other accessories are not included — these must be selected to match your installation.

Accessories & Related Products

  • 6C keystone data modules (RJ45 Cat6, HDMI, USB-C etc) to populate the cut-outs.

  • Flexible conduit/hose to enter via the keyed gland holes (32 mm or 35 mm) depending on your site standard.

  • Labelling kits to identify the box and its port terminations for future servicing.

  • Complementary P-Pack power modules (under-desk or desktop) if you are installing a full power/data infrastructure.

Ordering & Delivery

  • Add the unit to your basket via the “Add to basket” button on the product page.

  • Confirm the variant you need (horizontal vs vertical orientation, size/configuration of cut-outs) and select any required accessories.

  • Free delivery may apply on orders over your threshold


Contact & Support

For help selecting the correct model, matching conduit or determining how many 6C modules you need, please contact us at info@dataroomdirect.com or call 0800 852 1010. Our team will assist in ensuring you get the correct configuration for your workspace.


Ready to streamline your sub-floor data infrastructure?
Click “Add to basket” now to secure the P-Pack Databox unit and ensure your data installation is tidy, professional and future-ready.