Horz 4-way C19 with 2x C19 and covered 16A MCB per branch circuit, 3-metre 4mm LSZH to 32A commando
£149.00
Description
Horizontal 4-Way C19 PDU with 2-Branch Circuits & Covered 16 A MCBs

Key Features
-
1.5 U horizontal rack-mount unit with four IEC C19 output sockets.
-
Split into two branch circuits, each circuit individually protected by a covered 16 A MCB — enhances safety and load balancing.
-
Supplied with a 3-metre LSZH 4.0 mm² cable terminating in a 32 A Commando plug (standard for this model).
-
Robust construction: aluminium extrusion body, PVC socket fascia, 2 mm steel end-caps.
-
Complies with UKCA/CE electrical safety standards; rated for 250 V.
Technical Specifications
| Parameter | Specification |
|---|---|
| Rack Height | 1.5 U horizontal |
| Outlet Sockets | 4 × IEC C19 |
| Branch Circuits | 2 circuits, each protected by 16 A MCB |
| Lead Length | 3 m LSZH 4.0 mm² (to Commando plug) |
| Plug Input | 32 A Commando standard (other options available) |
| Construction | Aluminium body, steel end-caps |
| Maximum Voltage | 250 V |
Why Choose This PDU?
This PDU is ideal when you have rack-mounted equipment requiring C19-type outlets and want a high-quality professional solution rather than a basic power strip. The dual-branch design with individual MCBs means one branch can be isolated or faulted without affecting the other — which is especially useful in data-centre or network cabinet environments where reliability matters. The 1.5 U footprint keeps rack space usage minimal, and the robust build ensures long-term durability.
Applications & Use Cases
-
Rack cabinets powering high-current devices (servers, blade systems, network appliances) requiring IEC C19 connections.
-
Environments where load balancing and circuit protection are important (e.g., data rooms, comms racks, broadcast installations).
-
Installations where professional-grade power distribution is needed to meet regulatory or client-spec requirements.
Ordering & Custom Options
-
Choose your input plug/inlet: standard 32 A Commando is default, but other plug types (13 A UK, IEC C14/C20, 16 A Commando) may be available — contact us for alternatives.
-
Custom lead lengths, plug types, or alternate socket configurations may be offered — email info@dataroomdirect.com for bespoke.
-
SKU: HC19/4/EN/MCB (4-way C19 PDU, 2-branch circuits, 16 A MCBs) as per datasheet.
Pricing & Delivery
-
Available now at £149.00 (for the standard configuration).
-
Delivery: Typically 1-2 working days for stock models.
-
UK shipping policies apply; check for free-shipping thresholds on your website.
Installation & Compatibility Notes
-
Ensure your rack has clearance for a 1.5 U unit and the rear lead exit is managed for airflow and cable routing.
-
Before plugging in equipment, confirm your upstream power feed and breaker are sized appropriately for this PDU’s rating and planned load.
-
If using the two branch circuits, plan the device load on each branch to avoid tripping the 16 A MCB if one branch becomes overloaded.
-
Always follow relevant electrical safety standards and ensure proper earthing of rack and PDU.