Horizontal 2U 24-way IEC C13 16A PDU

High-density 24-way IEC C13 PDU for horizontal mounting in standard 19-inch server racks and network cabinets.

A 2U rack-mounted design with 24 IEC C13 outlets, 3-metre mains lead and master power switch. Ideal for powering multiple servers, switches and other rack-mounted equipment.

£93.00

SKU: H2UIEC/24 Category:

Description

2U 24-Way IEC C13 Rack Power Distribution Unit

High-density rack power distribution with 24 IEC C13 outlets in a horizontal 2U format.

This PDU is designed for standard 19-inch server racks and network cabinets, providing 24 IEC C13 outlets from a single rack-mounted power distribution unit.

Ideal for data centres, server rooms and communications installations where a high number of IEC-powered devices need to be connected within the rack.

Key Features

✓ 24 × IEC C13 outlets
✓ Horizontal 19-inch rack mounting
✓ 2U rack height
✓ 16A configuration
✓ 3-metre mains lead
✓ Aluminium extrusion housing
✓ Steel end caps
✓ Master power switch with indicator
✓ High-density power distribution for IT equipment

Technical Specifications

DRD Part Number H2UIEC/24
Mounting Horizontal 19-inch rack mount
Rack Height 2U
Output Sockets 24 × IEC C13
Maximum Voltage 250V
Standard Lead Length 3 metres
Cable 2.5mm² H05VV-F
Construction Aluminium extrusion with steel end caps
Input Connection As selected from the available plug options

High-Density Rack Power

With 24 IEC C13 outlets in a single unit, this PDU is particularly suitable for racks containing multiple servers, network switches, storage equipment and other IEC-powered devices.

The horizontal 2U design provides a high outlet count while keeping power distribution together in one easily accessible rack location.

Connecting Your Equipment

IEC C13 outlets accept compatible IEC C14 plugs. Equipment fitted with a C14 inlet can be connected using a suitable IEC C14 to C13 power lead.

Always check the electrical requirements of connected equipment and ensure the combined load remains within the rating of the complete PDU and its supply connection.

Installation

The PDU mounts horizontally into a standard 19-inch rack and occupies 2U of rack space. Allow sufficient clearance for power leads and cable management behind and around the unit.