Horizontal 12-way PDU with 10x C13 & 2x C19 in 2 branch circuits of 5+1 with 16A trips & neon power indicator

16A or 32A Plug

Enhanced PDU Datasheet

Generally in stock (1-2 working days)

£104.00

SKU: DRDHIEC10/C192/EN Category:

Description

Horizontal 12-Way PDU with 10× C13 & 2× C19 in 2 Branch Circuits of 5+1 with 16 A Trips & Neon Power Indicator

https://www.dataroomdirect.com/wp-content/uploads/2022/03/EN-IEC10C192-32A.jpghttps://www.dataroomdirect.com/wp-content/uploads/2022/03/VIEC12C194-EN-300x225.jpghttps://www.dataroomdirect.com/wp-content/uploads/2022/03/EN-PDU.jpg
6

Key Features

  • 1.5 U horizontal rack-mount format with 12 output sockets: 10 × IEC C13 + 2 × IEC C19.

  • Split into two branch circuits of 5 + 1 outlets, each protected by a 16 A thermal trip — improves safety and reduces single-point overload risk.

  • Supplied with a 3 metre lead as standard.

  • Multiple plug/inlet options available: BS1363 UK 13 A plug, IEC C14, IEC C20 plug, 16 A Commando, or 32 A Commando.

  • Neon power indicator to show live status clearly.

  • Designed to meet BS EN 60950 safety standard — suitable for professional rack installations.


Technical Specifications

Specification Details
Rack Height 1.5 U (horizontal)
Socket Configuration 10 × IEC C13 + 2 × IEC C19
Branch Circuits 2 circuits (5 + 1) each protected by 16 A trip
Plug/Input Options UK 13 A, IEC C14, IEC C20, 16 A Commando, 32 A Commando
Lead Length 3 m standard
Main Features Neon power indicator, rack-mount design, dual branch

Why Choose This PDU?

This horizontal PDU offers a versatile and professional solution for racks that combine both IEC C13 and C19 devices. The dual-branch circuit design means you can distribute load more effectively and mitigate the risk of a single overloaded circuit. With built-in protection (16 A trips), and a durable 1.5 U rack mount form-factor, it’s ideal for server racks, network cabinets, and data centre environments.


Applications & Use-Cases

  • Server racks where you have a combination of normal-draw equipment (C13) and higher-draw appliances (C19).

  • Network or comms cabinets where equipment density is high and power management needs to be organised across two independent branches.

  • Environments where safety and regulatory compliance are important — the 16 A circuit protection and BS EN 60950 design help meet professional standards.

  • Ideal for office data rooms, broadcast racks, IT closets, or any environment where rack space is valuable and efficient power distribution is required.


Ordering & Custom Options

  • Choose the input plug/inlet type at checkout (UK 13 A, IEC C14/20, Commando 16 A/32 A).

  • If you require a different lead length, bespoke socket configurations, surge protection, or alternate mounting form-factors (vertical 0U), contact us at info@dataroomdirect.com for tailored options.

  • SKU: DRDHIEC10/C192/EN.


Pricing & Delivery

  • Priced at £104.00 for the standard configuration.

  • Delivery: Generally in stock with 1-2 working days lead time.

  • UK standard delivery terms apply.


Installation & Compatibility Notes

  • Mount in a standard 19″ rack occupying 1.5 U height.

  • Ensure that the total connected load per branch is within 16 A to avoid tripping the circuit.

  • Route the 3 m lead appropriately for cable management and airflow.

  • Verify that the mains feed and the chosen plug/inlet type are compatible with your facility’s power infrastructure.

  • This is a professional-grade PDU; ensure installation is performed by qualified personnel and adheres to local electrical safety regulations.