Individually Fused IEC C13 Rack PDU – 10 & 12 Way

Individually fused IEC C13 PDU for professional 19-inch server racks and network cabinets.

Available in 10-way and 12-way configurations, with individual outlet protection, 1.5U horizontal mounting, a 3-metre mains lead and a choice of input connections.

£69.95£89.95

Description

Individually Fused IEC C13 Rack PDU

Individual fuse protection for each IEC C13 outlet in a professional rack-mounted power distribution unit.

This individually fused PDU is designed for server racks, network cabinets and data centre installations where additional outlet-level protection is required.

Available with 10 or 12 IEC C13 outlets, each outlet is individually fused rather than relying solely on protection for the complete PDU.

Key Features

✓ 10-way or 12-way IEC C13 configurations
✓ Each IEC C13 outlet individually fused
✓ Horizontal 19-inch rack mounting
✓ 1.5U rack height
✓ 3-metre mains lead supplied as standard
✓ Choice of input connections
✓ Professional server and data centre power distribution

Technical Specifications

Mounting Horizontal 19-inch rack mount
Rack Height 1.5U
Output Sockets IEC C13
Outlet Options 10-way or 12-way
Outlet Protection Individual fuse protection for each IEC C13 outlet
Standard Mains Lead 3 metres
Input Options 13A UK, IEC C14, IEC C20 or 16A Commando

Why Choose an Individually Fused PDU?

Individual outlet fusing provides dedicated protection for each connected circuit. This can be particularly useful in professional IT installations where multiple devices share a single rack PDU.

If a fault occurs on one connected circuit, its individual fuse provides localised protection rather than relying solely on the protection associated with the complete PDU and upstream supply.

10-Way & 12-Way Options

Choose the 10-way or 12-way configuration according to the number of devices in your rack and the available mounting space.

Select an input connection compatible with your mains supply or UPS output when ordering.

Connecting IEC Equipment

The IEC C13 outlets accept IEC C14 plugs. Equipment with a C14 inlet can be connected using a suitable IEC C14 to C13 power lead.

Always keep the combined connected load within the overall rating of the selected PDU and its input supply.

Need help specifying an individually fused PDU?
Call Data Room Direct on 0800 852 1010 or email info@dataroomdirect.com and we’ll help you select the correct configuration.

Additional information

Number Outlets

10 Way, 12 Way

Plug Option

13A UK, IEC C14, IEC C20, 16A Commando