Uniti Power UPS · Supplied by Data Room Direct

Keep your essential
systems powered.

Battery backup for office equipment, communications racks and server rooms. Compare the Uniti Power range, or work with DRD to specify a system around your load, runtime and installation.

Uniti Power Symphony rack and tower UPS, manufacturer product photograph

Start with the equipment you need to protect.Choose the capacity, backup time and physical format that suit your installation.

850VA to 10kVA across the rangeTower, rack and project systemsManufacturer technical documentation

Find your starting point

What are you protecting?

Start with your application, then check both the VA and watt ratings against your equipment. The backup time you need and the available installation space help narrow the choice.

Standard UPS selection

Compare the core range.

Seven models for office, network and server applications. Ask DRD to confirm the right configuration, current availability and delivery for your requirement.

Uniti Power Tempo TMP1200IEC tower UPS

A compact tower format for compatible office and network equipment.

Office equipment & everyday connectivity

Tempo

  • Line-interactive with AVR
  • Tower
  • Internal batteries

Protect compatible PCs, routers and small network installations against power interruptions. Automatic voltage regulation manages everyday supply changes, while USB connectivity supports controlled shutdown with compatible equipment.

Tempo model comparison
Manufacturer modelPower rating
TMP850IEC850VA / 480W
TMP1200IEC1,200VA / 600W
TMP2200IEC2,200VA / 1,200W

Tempo produces a stepped sine wave on battery. Confirm suitability for the connected equipment, the required leads and your backup time.

Uniti Power Echo ECH2000RMi2U rack UPS

428mm chassis depth. Allow the specified rear clearance and space for power connections.

Communications, networking & security racks

Echo

  • Online double-conversion
  • 2U rack
  • Internal batteries on 1kVA & 2kVA

Continuous online power protection in a compact rack format. The 1kVA and 2kVA models combine internal batteries with pure sine-wave output and no break in supply when switching from mains to battery operation.

Echo core model comparison
Manufacturer modelPower rating
ECH1000RMi2U1,000VA / 900W
ECH2000RMi2U2,000VA / 1,800W

Check the cabinet’s usable depth, load rating and mounting support. Network monitoring cards and the required accessory package should be specified for the model.

Uniti Power Symphony rack and tower UPS, manufacturer product photograph

A 2U rack or tower configuration, with compatible external battery options available to specify.

Servers, storage & essential IT

Symphony

  • Online double-conversion
  • Unity power factor
  • 2U rack / tower

The 1.5kVA and 3kVA Symphony models provide online protection with equal VA and watt ratings. Both include internal batteries, with compatible external battery modules available where the application needs longer backup time.

Symphony core model comparison
Manufacturer modelPower rating
SPY1500RMi2U445mm UPS depth1,500VA / 1,500W
SPY3000RMi2U605mm UPS depth3,000VA / 3,000W

Specify rack support, leads and monitoring with the UPS. The SPY3000RMi2U has an IEC C20 inlet and requires a separately specified input lead and suitable supply.

Engineered project solutions

Plan the complete backup power system.

For extended runtime, higher loads or a hardwired installation, start with your equipment and site requirements. DRD can take these to the manufacturer to confirm a suitable configuration and quotation.

ECH3000RMi2UER

Echo 3kVA ER

3,000VA / 2,700W

A 2U online power module for a separately configured battery system. No internal batteries: compatible EBM72VRM2U modules must be specified to provide backup.

Model datasheet (PDF)

SPY6KiRTB

Symphony 6kVA

6,000VA / 6,000W

A 5U rack/tower system with a 2U power module and supplied 3U battery module. Hardwired input and output require a suitable electrical installation and qualified installer.

Model datasheet (PDF)

SPY10KiRTB

Symphony 10kVA

10,000VA / 10,000W

A 5U rack/tower system with a supplied battery module for larger loads. Plan the supply, distribution, runtime, rack space and installation requirements as one system.

Model datasheet (PDF)

Need longer runtime, additional battery modules or help defining the requirement? Send us the equipment list and the backup duration you need.

Discuss a UPS project

Choose with confidence

Three checks that shape the right UPS.

1. The equipment load

Check the combined watts and VA of the equipment, including any start-up demand and planned growth. Both must be within the chosen UPS ratings. An equipment list is a useful starting point if you do not yet know the load.

2. The backup time

Decide how long the equipment must run during a power cut. Runtime changes with load, batteries and operating conditions. Compare manufacturer figures at your expected load, then specify any compatible external batteries needed.

3. The installation

Check the available supply, inlet and outlet types, rack height, usable depth and weight capacity. Allow ventilation and cable space. Confirm rails, leads, monitoring and any installation work in the agreed specification.

Talk to Data Room Direct

Tell us what needs to stay powered.

Send a model number or your equipment list. We can help narrow the options and check the required configuration, availability and quotation.

Call 0800 852 1010 · info@dataroomdirect.com

Useful details for your enquiry

  1. Equipment: model list, total load and any planned additions.
  2. Runtime: how many minutes of backup you need.
  3. Location: tower or rack, available space and power supply.
  4. Configuration: outlets, monitoring and any existing UPS or batteries.
  5. Delivery: quantity, postcode and required date.

Do not have all the details yet? Send what you have, including cabinet or equipment photographs where useful.

Before you choose

What is the difference between Tempo, Echo and Symphony?

Tempo is a line-interactive tower range for compatible office and smaller network equipment. Echo provides online double-conversion protection in a short-depth rack format. Symphony provides online rack/tower protection with unity power factor and compatible external battery options. Choose against the load, runtime, connections and installation requirements.

How long will a UPS keep my equipment running?

There is no single runtime for a UPS model. Backup duration depends on the connected load, battery configuration, battery age and temperature. Tell us the equipment load and required time so the manufacturer’s runtime data can be checked for your application.

Will a rack UPS fit my existing cabinet?

Check usable mounting depth and height, support rails, cabinet loading, cable space and the manufacturer’s ventilation clearances. A cabinet’s outside dimensions alone do not establish compatibility. Send the cabinet model or internal measurements with your enquiry.

Are batteries included with every model?

The seven core models above contain internal batteries. The Echo ECH3000RMi2UER has no internal batteries and needs separately specified battery modules. Symphony SPY6KiRTB and SPY10KiRTB include a separate 3U battery module as part of the listed 5U system. Check the complete configuration in your quotation.

How do I check price and availability?

Send the manufacturer model, quantity and delivery postcode, or use the enquiry form if you need help choosing. We will check the configuration, current price and expected dispatch information before you order.

What warranty applies?

Manufacturer warranty cover varies by product family and component, with separate terms for batteries. Registration and territory conditions apply. Refer to the current Uniti Power warranty terms and confirm the applicable support arrangements with your quotation.