Uniti Power UPS · Supplied by Data Room Direct
Keep your essential
systems powered.
Battery backup for office equipment, communications racks and server rooms. Compare the Uniti Power range, or work with DRD to specify a system around your load, runtime and installation.
Start with the equipment you need to protect.Choose the capacity, backup time and physical format that suit your installation.
Find your starting point
What are you protecting?
Start with your application, then check both the VA and watt ratings against your equipment. The backup time you need and the available installation space help narrow the choice.
Office & small network
A workstation, router or small group of devices.
Compact tower models with line-interactive protection and automatic voltage regulation.
Explore TempoNetwork & comms rack
Online protection where rack depth matters.
Short-depth 2U UPS models for compatible communications, security and IT racks.
Explore EchoServers & storage
Online backup for essential IT loads.
Rack or tower models with unity power factor and options to specify additional battery runtime.
Explore SymphonyStandard UPS selection
Compare the core range.
Seven models for office, network and server applications. Ask DRD to confirm the right configuration, current availability and delivery for your requirement.
A compact tower format for compatible office and network equipment.
Office equipment & everyday connectivity
Tempo
- Line-interactive with AVR
- Tower
- Internal batteries
Protect compatible PCs, routers and small network installations against power interruptions. Automatic voltage regulation manages everyday supply changes, while USB connectivity supports controlled shutdown with compatible equipment.
| Manufacturer model | Power rating |
|---|---|
| TMP850IEC | 850VA / 480W |
| TMP1200IEC | 1,200VA / 600W |
| TMP2200IEC | 2,200VA / 1,200W |
Tempo produces a stepped sine wave on battery. Confirm suitability for the connected equipment, the required leads and your backup time.
428mm chassis depth. Allow the specified rear clearance and space for power connections.
Communications, networking & security racks
Echo
- Online double-conversion
- 2U rack
- Internal batteries on 1kVA & 2kVA
Continuous online power protection in a compact rack format. The 1kVA and 2kVA models combine internal batteries with pure sine-wave output and no break in supply when switching from mains to battery operation.
| Manufacturer model | Power rating |
|---|---|
| ECH1000RMi2U | 1,000VA / 900W |
| ECH2000RMi2U | 2,000VA / 1,800W |
Check the cabinet’s usable depth, load rating and mounting support. Network monitoring cards and the required accessory package should be specified for the model.
A 2U rack or tower configuration, with compatible external battery options available to specify.
Servers, storage & essential IT
Symphony
- Online double-conversion
- Unity power factor
- 2U rack / tower
The 1.5kVA and 3kVA Symphony models provide online protection with equal VA and watt ratings. Both include internal batteries, with compatible external battery modules available where the application needs longer backup time.
| Manufacturer model | Power rating |
|---|---|
| SPY1500RMi2U445mm UPS depth | 1,500VA / 1,500W |
| SPY3000RMi2U605mm UPS depth | 3,000VA / 3,000W |
Specify rack support, leads and monitoring with the UPS. The SPY3000RMi2U has an IEC C20 inlet and requires a separately specified input lead and suitable supply.
Engineered project solutions
Plan the complete backup power system.
For extended runtime, higher loads or a hardwired installation, start with your equipment and site requirements. DRD can take these to the manufacturer to confirm a suitable configuration and quotation.
ECH3000RMi2UER
Echo 3kVA ER
3,000VA / 2,700WA 2U online power module for a separately configured battery system. No internal batteries: compatible EBM72VRM2U modules must be specified to provide backup.
Model datasheet (PDF)SPY6KiRTB
Symphony 6kVA
6,000VA / 6,000WA 5U rack/tower system with a 2U power module and supplied 3U battery module. Hardwired input and output require a suitable electrical installation and qualified installer.
Model datasheet (PDF)SPY10KiRTB
Symphony 10kVA
10,000VA / 10,000WA 5U rack/tower system with a supplied battery module for larger loads. Plan the supply, distribution, runtime, rack space and installation requirements as one system.
Model datasheet (PDF)Need longer runtime, additional battery modules or help defining the requirement? Send us the equipment list and the backup duration you need.
Discuss a UPS projectChoose with confidence
Three checks that shape the right UPS.
1. The equipment load
Check the combined watts and VA of the equipment, including any start-up demand and planned growth. Both must be within the chosen UPS ratings. An equipment list is a useful starting point if you do not yet know the load.
2. The backup time
Decide how long the equipment must run during a power cut. Runtime changes with load, batteries and operating conditions. Compare manufacturer figures at your expected load, then specify any compatible external batteries needed.
3. The installation
Check the available supply, inlet and outlet types, rack height, usable depth and weight capacity. Allow ventilation and cable space. Confirm rails, leads, monitoring and any installation work in the agreed specification.
Talk to Data Room Direct
Tell us what needs to stay powered.
Send a model number or your equipment list. We can help narrow the options and check the required configuration, availability and quotation.
Useful details for your enquiry
- Equipment: model list, total load and any planned additions.
- Runtime: how many minutes of backup you need.
- Location: tower or rack, available space and power supply.
- Configuration: outlets, monitoring and any existing UPS or batteries.
- Delivery: quantity, postcode and required date.
Do not have all the details yet? Send what you have, including cabinet or equipment photographs where useful.
Before you choose
What is the difference between Tempo, Echo and Symphony?
Tempo is a line-interactive tower range for compatible office and smaller network equipment. Echo provides online double-conversion protection in a short-depth rack format. Symphony provides online rack/tower protection with unity power factor and compatible external battery options. Choose against the load, runtime, connections and installation requirements.
How long will a UPS keep my equipment running?
There is no single runtime for a UPS model. Backup duration depends on the connected load, battery configuration, battery age and temperature. Tell us the equipment load and required time so the manufacturer’s runtime data can be checked for your application.
Will a rack UPS fit my existing cabinet?
Check usable mounting depth and height, support rails, cabinet loading, cable space and the manufacturer’s ventilation clearances. A cabinet’s outside dimensions alone do not establish compatibility. Send the cabinet model or internal measurements with your enquiry.
Are batteries included with every model?
The seven core models above contain internal batteries. The Echo ECH3000RMi2UER has no internal batteries and needs separately specified battery modules. Symphony SPY6KiRTB and SPY10KiRTB include a separate 3U battery module as part of the listed 5U system. Check the complete configuration in your quotation.
How do I check price and availability?
Send the manufacturer model, quantity and delivery postcode, or use the enquiry form if you need help choosing. We will check the configuration, current price and expected dispatch information before you order.
What warranty applies?
Manufacturer warranty cover varies by product family and component, with separate terms for batteries. Registration and territory conditions apply. Refer to the current Uniti Power warranty terms and confirm the applicable support arrangements with your quotation.