- Please specify the product required option(s).
Vertical 16-way PDU with 12x C13 & 4x C19 in 2 branch circuits of 6+2 with 16A trips, neon and digital amp meter
£169.00
Description
Vertical 16-Way PDU (12× C13 + 4× C19) Dual Branch, 16 A Trips, Neon & Digital Ammeter
Key Features
-
Vertical mounting (0 U) designed for rack-side installation — ideal for high-density server cabinets.
-
16 output sockets: 12 × IEC C13 and 4 × IEC C19 — supports a mix of standard and higher-current rack devices.
-
Two independent branch circuits (6 + 2 outlets) each protected by a 16 A thermal trip — enhances load distribution and safety.
-
Built-in neon power indicator plus digital ammeter display for real-time current monitoring.
-
Standard 3 m feed lead; plug input options include BS1363 UK, IEC C14, IEC C20, 16 A Commando or 32 A Commando.
-
Rugged construction designed to meet BS EN 60950-compliant standards for professional rack installations.
Technical Specifications
| Specification | Details |
|---|---|
| Output Sockets | 12 × IEC C13 + 4 × IEC C19 |
| Branch Circuits | 2 branches (6 + 2 outlets) with 16 A trips |
| Mounting | Vertical 0 U rack side |
| Lead Length | 3 metre feed lead |
| Plug/Input Options | BS1363 UK / IEC C14 / IEC C20 / 16 A Commando / 32 A Commando |
| Indicators & Monitoring | Neon power indicator; digital ammeter display |
| Standards | BS EN 60950 compliant |
Why Choose This PDU?
This PDU offers an excellent solution for racks hosting both lower-current devices (via C13) and higher-current devices (via C19) in one compact vertical unit. The dual-branch circuit architecture with independent 16 A trips helps prevent overloads on a single circuit while the digital ammeter makes ongoing monitoring effortless. The 0 U format ensures maximum rack equipment space is preserved.
Applications & Use-Cases
-
High-density server racks or data cabinets requiring mixed outlet types and monitoring capability.
-
IT, broadcast or comms rooms where real-time rack power usage on each branch must be visible and managed.
-
Network closets or edge data centres where rack space is at premium and vertical side-mount PDUs are preferred.
-
Installations requiring professional-grade power distribution that comply with safety standards and offer monitoring features.
Ordering & Custom Options
-
Choose the feed plug/inlet type that matches your site (UK BS1363, IEC C14/C20, 16 A or 32 A Commando).
-
If you require custom lead lengths, mixed socket counts, or additional features (e.g., surge protection), contact us at info@dataroomdirect.com for bespoke quoting.
-
SKU: VIEC12/C194/EN (as listed).
Pricing & Delivery
-
Price: £169.00 (standard configuration).
-
Generally in stock with a lead time of 1-2 working days.
-
UK delivery terms apply.
Installation & Compatibility Notes
-
Mount along the rack side or rear upright to maximise space efficiency.
-
Ensure your rack feed supply, breaker and socket match the plug/inlet type selected.
-
Monitor each branch load to remain within the 16 A trip limits to avoid nuisance tripping.
-
Use cable management to maintain airflow clearance around rack and PDU.
-
Comply with site earthing and electrical installation regulations for safe operation.