Vertical IEC PDUs
Vertical IEC PDUs, designed to fit into server and data cabinets
£35.00
Description
Vertical IEC PDUs
Key Features
-
Purpose-designed 0 U vertical rack-mount PDU with IEC C13 sockets, optimised for server cabinets and data-centre racks.
-
Supplied with a 3 metre lead as standard (custom lengths available) and multiple plug options (UK 13A, IEC C14, IEC C20, 16A/32A Commando).
-
Robust steel/chassis construction with black powder-coat finish, rear-mounting profile to minimise footprint in the rack.
-
Available in multiple outlet-counts (e.g., 6, 8, 10, 12, 16, 20, 24 ways) to suit different rack power-distribution needs.
Technical Specifications
| Parameter | Specification / Options |
|---|---|
| Mounting Format | 0 U vertical mount (along rack uprights, rear or side) |
| Socket Type | IEC C13 (16A rated for typical units) |
| Lead Length | 3 m standard |
| Plug / Inlet Options | UK 13A, IEC C14, IEC C20, 16A Commando, 32A Commando |
| Outlet Counts Available | From ~6 up to ~24 (depending on model) |
| Construction | Steel chassis with textured black powder-coat finish |
Why Choose This PDU?
-
When your rack layout demands maximum vertical space efficiency, this vertical-mounted PDU occupies no U-space (0 U) and runs alongside uprights or the cabinet side – freeing more rack height for equipment.
-
Ideal for racks with many IEC-plugged devices (servers, network appliances, storage units) — gives you a consolidated distribution unit without needing multiple horizontal strips.
-
Flexible plug/inlet options make it easy to match mains feeds, whether standard UK plug, higher capacity, or international/infrastructure uses.
-
Heavy-duty build quality ensures reliability and durability in professional installations, not just consumer-grade strips.
Applications & Use-Cases
-
High-density server racks and data centre enclosures where equipment uses IEC C13 connections and space is premium.
-
Network closets, comms rooms or broadcast racks where vertical power distribution allows better cable routing and airflow.
-
Installations where future scalability is expected — choosing a higher-outlet count version means you minimise future PDUs and maintain a cleaner setup.
-
Situations where rack space is precious and 1.5 U or 2 U horizontal PDUs are unacceptable from a space-utilisation perspective.
Ordering & Custom Options
-
Choose your outlet-count model (e.g., 8-way, 12-way, 16-way, 24-way) depending on rack load and devices.
-
Select your plug/inlet type to match your site’s mains feed or UPS output.
-
If you require longer lead length, custom socket mixes (IEC C13 + C19), surge-filtering, monitoring, or custom finish/colour, contact us at info@dataroomdirect.com for a tailored quote.
-
Standard-models ready to order; bespoke variants may incur longer lead time.
Pricing & Delivery
-
Entry-level models start from around £35.00 (as listed on site for vertical IEC PDUs) for the simplest configuration.
-
Price increases apply for higher-way counts, premium plug/inlet options or added features (surge protection, monitoring).
-
UK shipping & delivery terms apply; check for free-delivery thresholds or expedited shipping options.
Installation & Compatibility Notes
-
Mount the unit to the rack’s side-uprights or rear panel in the cabinet, ensuring cable access and ventilation are maintained.
-
Ensure all devices plugged into the PDU are within the rated load of the PDU and that upstream feed (breaker, UPS) supports total load plus margin.
-
Use proper cable management to keep the PDU lead and connected device cables away from hot-spots and ventilation flows.
-
If the chosen plug/inlet is a Commando or IEC C20, ensure the site socket or UPS output matches — mismatches may cause compatibility or safety issues.