Vertical UK PDUs with Surge Protection Options
Vertical UK PDUs – 0U Rack Mount Power Units
Vertical UK socket PDUs for server racks and network cabinets, with a space-saving 0U mounting format.
Supplied with a 3-metre mains lead and covered master switch. Choose the required socket configuration and input plug, with surge/filter protection available on selected models.
vertical UK PDU Datasheet
£35.00
Description
Vertical UK Rack PDUs for Server & Network Cabinets
Distribute power to UK-plug equipment without using valuable front-facing rack space.
These vertical UK power distribution units mount inside server racks and network cabinets, providing accessible sockets for IT and networking equipment. The 0U format positions power alongside the equipment rather than occupying horizontal rack mounting space.
A durable aluminium housing, covered master switch and 3-metre mains lead provide a practical power distribution solution for server rooms, communications cabinets and data centre installations.
Key Features
✓ Space-saving 0U vertical mounting
✓ UK BS1363 socket outlets
✓ Durable aluminium housing
✓ Master power switch with protective cover
✓ 3-metre mains lead supplied as standard
✓ Choice of socket configurations and input plugs
✓ Surge/filter protection available on selected models
Technical Specifications
| Mounting format | 0U vertical mounting within a suitable server or network cabinet |
|---|---|
| Output sockets | UK BS1363 Type G |
| Socket quantity | As selected from the product options |
| Housing | Aluminium extrusion |
| Standard mains lead | 3 metres |
| Cable exit | Through the end cap |
| Power switch | Master switch with protective cover |
| Input connection | As selected from the plug options |
| Surge/filter protection | Included only on the relevant surge/filter versions |
Standard & Surge/Filter Options
Choose a standard unit for straightforward rack power distribution, or select a surge/filter version where additional protection against voltage spikes is required.
Surge/filter protection is not included on standard models. Select the appropriate version from the product options when ordering.
Choosing the Correct Vertical PDU
Check the required socket quantity, input connection and available mounting space inside your cabinet. The unit length depends on the configuration, so confirm the dimensions of your chosen model before ordering.
The total connected load must remain within the rating of the selected PDU and its input connection. Individual socket ratings should not be added together to calculate the capacity of the complete unit.