921a2bb2-176a-43d4-ac13-0fecfe490d92
EN Cropped
EN PDU
EN PDU 1
921a2bb2-176a-43d4-ac13-0fecfe490d92
EN Cropped
EN PDU
EN PDU 1
Full Screen

Vertical 16-Way IEC C13 PDU – Dual 16A Branch with Ammeter

Vertical 16-Way IEC C13 PDU – Dual 16A Branch with Ammeter. The outlets are divided between two separately protected branches; each branch and the overall input must remain within their stated ratings.

Confirm mounting fit, input compatibility and the total connected load before ordering.

Price range: £160.00 through £168.50 ex VAT Price range: £192.00 through £202.20 inc VAT

SKU: DRD-VIEC16/EN Category:

Description

Vertical 16-Way IEC C13 PDU – Dual 16A Branch with Ammeter

Vertical 16-Way IEC C13 PDU – Dual 16A Branch with Ammeter. The outlets are divided between two separately protected branches; each branch and the overall input must remain within their stated ratings.

Plan your setup

Match outlet type, connecting leads and input connection to the equipment and supply. Check mounting dimensions and allow clearance for cables and cabinet access. The total load is limited by the complete PDU and its input supply.

Key features

  • Two separately protected branches.
  • 16A protection per branch.
  • Digital ammeter for current monitoring.

Choose your setup

  1. Match the output sockets or charging ports to your equipment.
  2. Check branch loads as well as the total input load.
  3. Confirm mounting dimensions, cable clearance and the complete unit rating.

Technical specifications

Mounting Vertical rack mounting
Total Outlets 16
Output Socket Type IEC C13
Branch Circuits 2 independent circuits
Outlets Per Branch 8 × IEC C13
Branch Protection 16A protection per branch
Current Monitoring Digital ammeter
Power Indication Neon indication
Input Connection Refer to selected product configuration
Overall Electrical Rating Refer to the rating marked on the supplied PDU
Input Option 16A; 32A

Frequently asked questions

Do more outlets increase the total power capacity?

No. Individual socket ratings do not add together to give the unit’s capacity. Keep the combined load within the marked PDU and supply ratings.

Does this provide two separate input supplies?

This is a branched PDU. Separately protected branches do not by themselves mean redundant or independent mains feeds. Check the selected input arrangement.

Need help choosing?

Call 0800 852 1010 or contact Data Room Direct for help with product selection, project quantities and delivery times.

Additional information

Input Option

16A, 32A